Rolling Stock Cables | ||||||||||||||||||
|
WTB (Wired Train Bus) / MVB (Multifunction Vehicle Bus) Cables
FRL-WTB/MVB-02Y(ST+C)H-1P20A
A. Conductor B. Insulation C. Screen D. Sheath
Application
The cables are designed for permanent installation inside of rolling stock to connect fixed parts. A typical
application is a communication system in a locomotive. The system uses a wire backed bus system to the TCN
standard for control and instrumentation and for diagnostics. This bus system consists of the rail bus WTB
(Wired Train Bus) and the road bus MVB (Multifunction Vehicle Bus) which are connected via redundant
gateways.
Construction
Conductors
Stranded tin plated copper conductor according to IEC 60228 class 5
Insulation
Foam PE or Foam Skin
Cable Element
Twisted pair
Core Wrapping
Plastic tape(s)
EMC Screen1
Aluminium clad polyester foil
EMC Screen2
Tin plated copper braid
Core Wrapping
Plastic tape(s)
Outer Sheath
Cross-linked oil resistant LSZH compound
Electrical & Mechanical Properties
Nominal Voltage:300V
Maximum Conductor Temperature:100℃
Minimum Permissible Ambient Temperature:-40°C
Bending Radius:12 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2:No fluorine
EN 50305; EN 60811-2-1:Resistance to mineral oil & fuel oil, acid & alkali
EN 50305:Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2:Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2:Protection level 1/2/3/4
BS 6853:Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101:FO
EN45545-2:R15 Interior/ R16 Exterior HL1, HL2, HL3
Fire Performance in general
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 |
Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 |
Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 | Low Toxicity |
NFF 16101; NFF 63808; BS6853 | Smoke index |
EN45545-2 | Requirement for fire behavior of materials & components R15/R16 |
FRL-WTB/MVB-02Y(ST+C)H-1P20A
Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Maximum Conductor Resistance | Impedance | Maximum Attenuation | ||
20°C | @0.75-3MHz | @1MHz | @2MHz | ||||||
mm2 | AWG | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km |
0.62 | 20 | 19/0.2 | 1.2 | 8.3 | 80 | 33.1 | 120+/-12 | 10 | 15 |